QuickSpecs
HP EliteDesk 800 G1 Series Business Desktop
Technical Specifications Power
WorldwideVersion 1.2 December 3, 2013 Page 63
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit
is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's
re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other
foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Operating: 50° to 95° F (10° to 35° C)*
Non-operating: 22° to 140° F(30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum
Altitude (unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
DM
USDT
SFF
TWR
Standard Efficiency
65W active PFC
87% efficient
Integrated
graphics:
135W active PFC
87% efficient
240W active PFC
320W active PFC
Discrete
graphics:
180W active PFC
87% efficient
80 PLUS Gold
N/A
N/A
240W active PFC
87/90/87% efficient at
20/50/100% load (115V)
89/91/90% efficient at
20/50/100% load (230V)
320W active PFC
87/90/87% efficient at
20/50/100% load (115V)
89/92/90% efficient at
20/50/100% load (230V)
80 PLUS Platinum
N/A
N/A
240W active PFC
90/92/89% efficient at
20/50/100% load (115V)
90/93/91% efficient at
20/50/100% load (230V)
320W active PFC
90/92/89% efficient at
20/50/100% load (115V)
90/94/91% efficient at
20/50/100% load (230V)
Operating Voltage Range
90 - 264 VAC
90 - 264 VAC
90 - 264 VAC
90 - 264 VAC
Rated Voltage Range
100 - 240 VAC
100 - 240 VAC
100 - 240 VAC
100 - 240 VAC
Rated Line Frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Operating Line Frequency
47 63 Hz
47 63 Hz
47 63 Hz
47 63 Hz
Rated Input Current
N/A
N/A
4A
5.5A
Rated Input Current with
135W: 2.4A
4A
5.5A